Step 1 Create Logical Drive

This section describes how to create a logical drive on RAID-0.

To create a logical drive on RAID-0:
1. Power up the server. If the server is already powered up and running, use the 'reboot' command (from system console as user root) to reboot the server.
2. While the server is powering up, monitor the server.
3. During restart, press <F9> to open the System Utilities.
4. Choose Embedded Applications > Intelligent Provisioning > Smart Storage Administrator.
5. Wait for the Smart Storage Administrator utility to finish loading.
6. In the left-hand pane, choose HPE Smart Array ControllersHPESmart Array E208i-a SRGen10; an Actions menu is displayed.
7. Click Configure, and then click Clear Configuration to clear any previous configuration.
8. Click Clear to confirm; a summary display appears.
9. Click Finish to return to the main menu.
10. In the left-hand pane, select Unassigned Drives (2); make sure that both the drives are selected, and then click Create Array.
11. Select RAID 0 for RAID Level.
12. Select the 'Custom Size' check box, and then enter 2000GiB.
13. At the bottom of the screen, click Create Logical Drive.

After the array is created, a logical drive should be created.

14. Click Finish.
15. Proceed to Section Step 2 Set Logical Drive as Bootable Volume